InTek Hybrid OPC Server
-
Related Documents
Related Softwares -
InTek Hybrid OPC Server is the first OPC Server product in the world that capable to run multi-protocol over single serial communication port/channel.
The Serial protocols that currently supported by InTek Hybrid OPC Server are :
IEC 60870-5-101IEC 60870-5-103DNP 3.0 Serial Level 1, 2, and 3DLMS / CosemFLAG / IEC 61107 / IEC 62056Modbus RTU / Jbus / ASCIIABB SPAbusEDF HNZ (multi versions)
and all of the above (or combination of several protocols) could be set to run on single serial port, such as single Radio channel, one Power Line Carrier channel, etc.
InTek Hybrid OPC Server also supports Ethernet TCP/IP protocols such as :
IEC 60870-5-104DNP 3.0 over LAN/WANModbus TCP/IPIEC 60870.6 Tase.2IEC 61850 / UCA.2
Support the utilization of Port Server (Serial to Ethernet) for serial communication over Ethernet TCP/IP network.
InTek Hybrid OPC Server featured with Hot-standby redundancy, in terms of :
Channel redundancyComputer redundancy
Facilities for devices template (pre-define devices with all of its tags) allow the user to just select that Device without any requirement to define any tags further.
Also, the template will include direct collection of the historical log within the device, and the collection could be triggered by a point change and/or periodic regular base.
The acquired history log will be directly presented as interpreted data on CSV/text file, or any other required file format.
With this template capability, build-up OPC Server database could be done less than one hour to define hundreds of Devices (that already has a template database).
Currently, InTek Hybrid OPC Server already has a built-in Database/Tags Template and Historical collection for the following IED (Intelligent Electronic Device) :
IEC 60870-5-103 Siprotec 7SJ60**IEC 60870-5-103 Siprotec 7SJ61**IEC 60870-5-103 Siprotec 7SJ62**IEC 60870-5-103 Siprotec 7SJ63**IEC 60870-5-103 Siprotec 7UT51**IEC 60870-5-103 Siprotec 7UT61**IEC 60870-5-103 Siprotec 7UM61**IEC 60870-5-103 Standard (with standard tags)Schneider MG Sepam 2000Schneider MG Sepam 1000+ S40ABB SPAJ 140C Protection RelayABB SPAJ REJ525 Protection RelayPML ION-7xxx series Power MonitorHC 6xxx series Power MonitorKeltronics ESP (Electrical Submersible Pump) ControllerVortex ESP (Electrical Submersible Pump) ControllerCTI ESP (Electrical Submersible Pump) Controller      (please contact us to find the latest IED devices list that we have supported)
The InTek protocols scanner, that is part of the InTek Hybrid Multi OPC Server, capables to acquire directly any of IED's historical/log data, and present it as TXT and/or CSV file, independently to the OPC interface.
Any historical data collected by the IED that accessible via standard protocol could be collected by the OPC protocol scanner, such as Well start/stop summary, failure condition list, snapshot periodic measurement, etc.
Disturbance Log (Fault Recording / Waveform capture) for Siprotec Relays or any Relay that support IEC 60870-5-103 protocol, will be presented as .TXT file under Logs directory/folder, and could be imported by MS Excel for viewing as waveform graph to trace the fault and occurred time.
Fault recording time and history of event on the Digital Protection Relay could be acquired directly by InTek Protocol scanner.
Max/Min recorder value/time on Digital Power Meter (DPM), as well as the Waveform Capture on Power Quality Meter, are also available to be handled by the InTek Protocol scanner.
For non-RBE (report-by-exception) protocol, such as Modbus, InTek Hybrid OPC Server has a special feature such as :
Real-Time PollPeriodic PollOn-Demand Poll - drive by OPC Client
With the facilities to arrange the polling group, user could select and achieve the most efficient polling cycle rate as per their system requirement, for example :
Just select the most important data to be poll as real-timeAssign the regular data to be polled periodically (eg. 5 minutes, 15 minutes, hourly, three times a day, daily, etc.)Perform on-demand poll whenever they required for any data/tag
The InTek Hybrid OPC Server also featured with communication analyst, such as :
Data communication (protocol raw-data, presented on native Hex value) log, and could be connected to the off- line InTek Protocol Analyzer for further review.Number of connected OPC Clients to InTek Hybrid Multi OPC Server, and the count number is presented as an Internal Tag that could be accessed by any OPC Client
Our InTek Hybrid OPC Server has been tested to interface with the following OPC Clients :
Wonderware InTouch via Wonderware OPClinkCitect via Citect OPC Client I/O DriverDeltaV via DeltaV OPC Mirror and Matrikon Data ManageriFIX +iPower via OPC ToolsZenon via OPC Client I/O DriverMatrikon OPC ExplorerSiemens OPC Scout